tretford

INSTALLATION CHECKLIST

KEY POINTS FOR INSTALLATION SUCCESS

Step 1:

Acclimatise

For 24 hrs on site before installation

  • Please remove plastic wrap beforehand
  • Do not install where substrate temp is under 10°C
  • Do not install where ambient humidity (RH) levels > 75%

Step 2:

Allow enough time

Do not lay in wet. Adhesive must achieve tack-off / tack-up.

Time will be dependent on temperature, humidity, airflow and substrate absorbency.

  • T240 | SynSisal S340 | Nexus 880 –  Place a small piece of carpet or finger into the adhesive. When pulled away, strings or cobwebs should be apparent.
  • Modu-Tak PS –  Allow adhesive film to become “translucent”. Once translucent, the adhesive is in a dry tack mode and ready.

Step 3:

Use correct adhesive and underlays

ROLL & RUGS

DIRECT STICK:

Adhesive: tretford 240
Substrate to tretford – use V2 (2.4mm) notched trowel (3m² per litre)

DUAL BOND:

Adhesive: tretford 240
Substrate to underlay – use V1 (1.6mm) notched trowel (5m² per litre)
Underlay to tretford – use V2 (2.4mm) notched trowel (3m² per litre)

Underlays:
– Airstep BOUNCE 470 – 4.7mm
– Airstep BOUNCE 650 – 6.5mm (Domestic only)
– Dunlop TECHNICS 5 – 5mm
– Dunlop PERFORMA 5 – 5mm
– Dunlop DURAFIT 7 – 7mm (Domestic only)

TILE

  • Adhesive: Modu-Tak – apply using V1 notched trowel

PLANK

  • Adhesive: tretford 240 – apply using V1 notched trowel
  • Adhesive: SynSisal S340 – apply using V1 notched trowel
  • Adhesive: Nexus 880 – apply using V1 notched trowel

Step 4:

Upon completion : Do not cover with impervious materials.

TEMPORARY PROTECTION:

Caution:— If impervious protective covering materials are applied over the newly installed product, condensation may collect under the covering and cause serious damage to the textile floor covering and/or bond strength of the textile floor covering to the substrate. ( AS/NZS:2455.1:2019).   Damage would not be covered under manufacturer’s warranty.